Gallagher Multi-Power Fence Enegizer
3E4345 MBS1000i MBS1800i MBS2800i Energizer User Manual
Gallagher 3E4345 MBS1000i MBS1800i MBS2800i Energizer User Manual. (2.68 MB) - PDF

Overview
User Guide Download Information
Gallagher 3E4345 MBS1000i MBS1800i MBS2800i Energizer User Manual. (2.68 MB) - PDF
Instructions - ENG
Installatie instructies - NED
Notice d’installation - FRA
Betriebsanleitung - DEU
Monteringsvejledning - DAN
Instrucciones - ESP
Monteringsinstruktioner- SVE
Istruzioni per l’installazione - ITA
PRODUCT SPECIFICATIONS:
| MBS1000i | MBS1800i | MBS2800i | |
| Power consumption: |
10 W powered by 15 V adapter. 8 W powered by 12 V battery. |
16.5 W powered by 15 V adapter. 11.5 W powered by 12 V battery. |
20 W powered by 15 V adapter. 17 W powered by 12 V battery. |
| Stored Energy: | 10 J | 18 J | 28 J |
| Output Energy: | 7.7 J | 12.4 J | 15.6 J |
| Output Voltage (no load): |
8 kV | 8 kV | 8 kV |
BATTERY GUIDE:
The Energizer will automatically reduce its power usage if the battery is starting to go flat.
This will be achieved by reducing the energy in each pulse and increasing the interval between pulses.
| Voltage Display Range | Battery Capacity |
|---|---|
| 30 | 75% + |
| 20 | 60 - 70% |
| 15 | 50 - 60% |
| 10 | 40 - 50% |
| 6 | 20 - 40% |
The Energizer stops pulsing if the battery drops below 20% to prevent damaging the battery.
Gallagher Recommends:
Use 12 V deep cycle lead acid batteries.
Batteries of the same type and manufacture can be connected in parallel to increase capacity.
Store battery in a dry place between 0 oC and 30 oC.
Do not leave batteries below 50% charge (12.0 V) for a prolonged period of me.
Batteries must be in a well ventilated area while charging.
| Battery Capacity | Full Power Operation (days) |
| Required | MBS1000i | MBS1800i | MBS2800i |
|---|---|---|---|
| 100 Ah | 2 | 1.5 | 1 |
| 200 Ah | 4 | 3 | 2 |
| 300 Ah | 6 | 4.5 | 3 |