TooL Box

By Vet N Farm

 

Troubleshooting

 Common electric fencing issues & solutions

#1 Output Reading

Energizer is not on or there is no volt meter reading across the energizer output terminals with the energizer disconnected from the fence.

Potential Causes:

1) Mainline power outage or blown fuse on input circuit

Solution: Restore power or replace blown fuse

2) Energizer is switched off or in Standby mode

Solution: Check energizer “on-off” switch.

3) Dry cell batteries are dead; wet cell
batteries are discharged
Solution: Recharge or replace batteries

4) Battery terminals are corroded

Solution: Clean terminals

5) Energizer is faulty

Solution: Have energizer serviced

#2 Low Energizer Reading

Energizer is on, but volt meter reading is low across the energizer output terminals when disconnected from fence.

Potential Causes:

1) Weak batteries

Solution: Recharge or replace batteries

2) Battery terminals are corroded

Solution: Clean battery terminals Troubleshooting

3) Energizer is faulty

Solution: Send for repair

#3 Volt Meter Not Reading

Energizer is operating, but there is no volt meter reading on the fence with the energizer connected to fence and ground

Potential Causes:

1) Ground-return or fence lead-out wire is disconnected or broken

Solution: Connect or repair fence or ground-return wire

2) Broken, corroded or disconnected live wire or ground-return on fence

Solution: Connect or repair live wire or ground-return on fence

3) Soil is dried out

Solution: Install ground-return wire

#4 Low Location Readings

Low volt meter readings at several locations on fence

Potential Causes:

1) Energizer is on low setting or is inadequate for length of fence

Solution: Switch energizer to high setting; install more powerful Energizer

2) Weak batteries

Solution: Recharge or replace batteries

3) Terminals corroded

Solution: Clean terminals

4) Ground system is inadequate or deteriorated

Solution: Repair or replace ground system

5) Soil is dried out

Solution: Install ground-return wire

6) The fence has faults

Solution: Repair fence faults

#5 No Location Readings

No volt meter readings at several locations on fence

Potential Causes:

1) Broken or disconnected fence wire, underground cable or ground wire

Solution: Connect or repair wire; remove cause of short; replace jumper connection

2) Ground rod connection deteriorated

Solution: Replace ground rod connection

3) A Cut Out Switch has been left open

Solution: Close Cut Out Switch

#6 Wire Reading levels

Volt meter reading on one wire is
higher than on another wire, or there
is no reading from one live wire to
ground-return or soil

Potential Causes:

1) Broken or disconnected fence wire, connecting wire or ground wire

Solution: Connect or repair wire; remove cause of short; replace jumper connection

2) Broken or faulty insulators

Solution: Replace faulty insulators

3) Ground connection rod deteriorated

Solution: Replace ground connection rod

#7 Signal interference

Radio, TV or telephone interference

Potential Causes:

1) Ground system inadequate

Solution: Increase grounding capacity

2) Antenna too close to fence

Solution: Relocate antenna or telephone wires

3) Fence is parallel with antenna wires or telephone lines

Solution: De-electrify or relocate segment of fence that is parallel to or too close to antenna or wires